Both swimming pools and water storage tanks face immense positive hydro static pressure. Underground water tanks or pools are also susceptible to water ingress from external sources like surrounding soil. Soluble salts in the soil can infiltrate the concrete and cause reinforcements attack if not waterproofed properly. Our comprehensive waterproofing treatment can keep the structure safe from all these. In Swimming Pools, its advisable to undertake two layer waterproofing. The first layer should be done on the concrete shell immediately after the concrete has been casted. The second layer after the surface has been plastered to take tiles. Our application includes:

  • Clean the surface properly by using mechanical grinders to grind and clean the concrete wall and floor slab.
  • Washing the surface with clean water to clean the deep pores of all the micro dust.
  • Plugging and Sealing all the electrical and plumbing points.
  • Saturate the surface with water based primers.
  • Application of 2 coats of Two Component Polymer modified flexible hydraulic micro mortar.
  • Water Ponding for 2 days to check for seepages if any.
  • Application of polymer modified Cement Mortar in ratio of 1: 4 (Cement : Coarse Sand).
  • Application of 2 coats of Two Component Polymer modified flexible hydraulic coating.
  • The surface will be ready to accept Tiles.

In water storage tanks, its advisable to use a chemical coating which is approved for contact with potable water. We also recommend to sue a coating which can be the final finish in the tank, without any need of plaster or tiles.
Our application includes;

  • Clean the surface properly by using mechanical grinders to grind and clean the concrete wall and floor slab.
  • Washing the surface with clean water to clean the deep pores of all the micro dust
  • Plugging and Sealing all the electrical and plumbing points.
  • Saturate the surface with water based primers
  • Application of 2 coats of Two Component Polymer modified flexible hydraulic micro mortar suitable for potable water OR 2 coats of Two Component Epoxy based coating suitable for potable water
  • Water Ponding for 2 days to check for seepages if any.

In the above application there is no need for any tiling or plastering the concrete wall. The difference between both the products is the quality of surface finish.